The HI98191 is a rugged, portable pH/ORP/ISE meter with the performance and features of a benchtop meter. This professional, waterproof meter complies with IP67 standards and measures pH, ORP, ISE, and temperature. The HI98191 is supplied with all necessary accessories to perform a pH/temperature measurement packaged into a durable carrying case.
  • CAL Check™
  • ISE in Choice of Concentration Units
  • Ergonomic, One-Handed Operation

For the measurement of pH the HI98191 comes with a HI72911B titanium body pH electrode with a built-in temperature sensor for automatic temperature compensated readings. The titanium body is chemically resistant to aggressive chemicals and is virtually unbreakable.

Hanna's unique CAL Check™ feature alerts the user to potential problems during the pH calibration process. By comparing previous calibration data to the current calibration the meter will alert the user with display prompts when the probe needs to be cleaned or is broken and if the pH buffer might be contaminated. After calibration the overall probe condition is displayed as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode and is displayed on the measurement screen on the day of calibration and in the GLP data. pH calibration can be performed up to five points with seven preprogrammed standard pH buffers and five custom ones to achieve a pH accuracy of ±0.002 with ±0.001 pH resolution.

The HI98191 has 15 different ISE sensors preprogrammed within the meter. By selecting the appropriate ISE in the ISE Setup Menu, the appropriate ion charge and ion molar weight are applied to display ISE slope percentage. Users can then calibrate up to five points with the choice of six standard values. This meter allows an extensive choice of measurement units (ppm, ppt, g/L, ppb, μg/L, mg/mL, M, mol/L, mmol/L, % w/v, user defined) and has an expanded measuring range of 1.00 x 10-7 to 9.99 x 1010.

Pressing the "AutoHold" virtual key seen in measurement mode, the meter will freeze a stable reading allowing for the reading to be documented or logged. An “out of calibration range” warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.

The log-on-demand mode allows the user to record and save up to 300 samples (100 each for pH, mV, and ISE). This data along with the associated GLP data can then be transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software.

Access help at any time at a press of a dedicated button and view content specific information based on the screen that is currently being viewed.

The high contrast graphic LCD is easy to read outdoors in bright sunlight as well in low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.

The compact, durable carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter, electrode and beakers.

 

On-screen features

 

Setup Screen

Our extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides. 

 

Calibration

pH calibration features detailed CAL Check™ messages. Alerts user to potential problems during calibration including when to clean electrode and possible buffer contamination. 

 

GLP

Comprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including: date, time, offset, slope and buffers used in the last calibration can be reviewed.

 

 

ISE Measurements

The HI98191 includes ISE measurements when used with our wide selection of ISE electrodes or a custom version.

 

Features and Benefits

 

Ergonomic, rugged, waterproof (IP67) design

pH CAL Check™

  • Alerts user to potential problems during calibration including when to clean electrode and possible buffer contamination.
  • Displays overall probe condition based on offset and slope after calibration

 

ISE direct concentration readout in a choice of concentration units

Automatic Temperature Compensation

Five-point pH calibration with seven standard buffers and five custom buffers

Log-on-demand

  • Store measurement data at the press of a button

AutoHold

  • Freezes a stable reading on the display for recording or logging

GLP features

  • GLP data including date, time, calibrated values, slope and offset (pH)

Calibration timeout to alert the user at a defined interval when the calibration has expired

Multiple language selection

200-hour battery life with battery level displayed on measurement screen

Menu driven for ease of use with virtual-key extended functionality

Contextual help at the press of a button Backlit, graphic LCD Connectivity

  • PC connectivity via a sealed opto-isolated micro USB and HI92000 software

 

Specifications

Specification Name Detail
sku HI98191
pH Range -2.0 to 20.0 pH / -2.00 to 20.00 pH / -2.000 to 20.000 pH
pH Resolution 0.1 pH / 0.01 pH / 0.001 pH
pH Accuracy (@25°C/77°F) ±0.1 pH / ±0.01 pH / ±0.002 pH
pH Calibration Up to five point calibration, seven standard buffers available (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and five custom buffers
mV Range ±2000.0 mV
mV Resolution 0.1 mV
mV Accuracy ±0.2 mV
Temperature Range -20.0 to 120.0 °C (-4.0 to 248.0 °F)
Temperature Resolution 0.1 °C (0.1 °F)
Temperature Accuracy (@25°C/77°F) ±0.4 °C (±0.8 °F) (excluding probe error)
ISE Range from 1.00 E⁻⁷ to 9.99 E¹⁰ concentration
ISE Resolution 3 digits 0.01; 0.1; 1; 10 concentration
ISE Accuracy ±0.5% of reading (monovalent ions), ±1% of reading (divalent ions)
ISE Calibration up to five point calibration, six standard solutions available (0.1, 1, 10, 100, 1000, 10000 ppm)
Temperature Compensation manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)
Log Feature On demand, 200 samples (100 pH and 100 mV)
Connectivity PC Connectivity - opto-isolated USB with optional HI 92000 software and micro USB cable
GLP Yes
Power Supply 1.5V AA batteries (4 pcs.)
Power Consumption approx. 200 hours of continuous use without backlight (50 hours with backlight)
Environment 6 to 50 °C (32 to 122 °F) max. RH 100% IP67
Dimensions 191 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight 406 g (14.2 oz)
Ordering Information HI98191 is supplied with HI72911B titanium body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700601 electrode cleaning solution sachet (2 x 20 mL), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual, quick start guide, instrument quality certificate, and HI720191 hard carrying case.
Recommended Probe HI72911B Titanium body, pH electrode with internal temperature sensor, BNC connector and 1 m (3.3’ cable)