HI510 is designed to adapt to a user’s unique process control requirements. The controller has a large backlit dot matrix display for easy viewing and provides for an intuitive interface for setup options. The controller utilizes multi-color LEDs for easy viewing of the instruments’ status including relay activation, in alarm mode, or in hold status. All programming operations are done through the low profile vulcanized rubber keypad or using the RS485 connection to a PC operating the HI92500 Windows® compatible software.

  • Digital input for pH and ORP probes
  • Up to 5 relays for control and cleaning sequence
  • Up to 4 analog output for control and monitoring

Kupujte z zaupanjem

Zahtevajte ponudbo

Počisti

Povprašajte za ponudbo

Izdelka ni mogoče kupiti prek spleta (on-line). Izpolnite obrazec, da prejmete ponudbo. Hvala Vam.

HI510 is an advanced universal process controller that can be configured for many applications requiring monitoring and/or control of process parameters. It features a digital probe input that will automatically detect and update the controller with the parameter that it measures.

This controller can be configured with up to 5 control relays and 4 analog outputs. The control relays can be programmed for on/off, Proportional, or PID (Proportional Integral Derivative) types of control or used for programming cleaning sequences triggered by a digital input or based on a schedule. The scalable analog outputs can be used for remote devices including Chart recorders, PLC, or SCADA. The analog outputs can be used for control devices including dosing pumps and valves that accept a 0/4-20 mA output.

HI510 features a RS485 digital output that allows up to 32 devices to be connected to a single line that can be viewed and programmed remotely using the HI92500 software. The HI92500software provides for graphic user interface that allows for settings to be changed and saved for transfer to another HI510 controller.

The HI510 NEMA 4X enclosure uses sealed cable glands to maintain waterproof integrity. The versatile mounting kits allow for mounting the HI510 to a wall, pipe and panel.

General Design Features

universal process controller
   


Backlit Dot Matrix LCD with LED indicators

Large backlit LCD with visual indicators for meter status, alarm and relay activation.

NEMA 4X Enclosure

½ DIN NEMA 4X enclosure suitable for outside and industrial environments.

Versatile Mounting Options

Choose from wall, pipe or panel mounted options.

USB-C Connectivity

universal process controller


Flash Drive Compatible

Transfer of logged data and events to a flash drive as a .csv file for review on Window’s, OS X, or Linux based computers.

Logged Data

Store information at selectable intervals along with relay control settings and calibrations data. Information can be stored in up to 100 lots, each holding 8600 records.

Event Management System

Logged events includes any changes made, alarm, error and warning activations, and calibration information.

Low Voltage Connections

HI510




Isolated High Voltage Section

To reduce the risk to shock the low voltage connection area is isolated from high voltage area.

RS485 Digital Connectivity

RS485 output for connecting up to 32 devices for remote monitoring and programming.

Digital Inputs and Analog Outputs

Digital probe input, digital trigger inputs, and analog outputs utilize extractable terminal blocks for simplified wiring.

High Voltage Connections



Replaceable Slow Blow Fuses

All relays and the line power input are protected by replaceable 5A slow blow fuses.

SPDT and SPST Programmable Relays

Up to 5 relays that can be programmed for control or washing sequences.

Fail Safe Alarm Technology

Fail Safe Alarm Technology that deactivates relay from normal open state to normally closed to supply power to remote alarm device.

Programming HI510 remotely using HI92500 Software

Relay Control Modes

Set points for control operations can be configured to be on/off, proportional, or PID types of control. The flexibility in programming allows for fine-tuning of a set point to be maintained with tight control preventing any overshoot and waste of chemicals.

Configurable Alarm System

Configurable for set points and temperature or activated by abnormal operation, a red Alarm LED will blink and can easily be seen from a distance. All relays configured for control are inactivated until the alarm state is resolved.

Auto-cleaning cycle

The cleaning function allows the ability to program one or more wash cycles and use the relays to activate valves, pumps or compressed air based on the type of washing that is required to maintain probes for reliable results.

Scalable Analog Outputs

Analog outputs can be scaled to assign 0 to 20 mA or 4-20 mA to a specific range for increased resolutions. Analog outputs can be programmed to send 22 mA signal when placed in hold status during maintenance including calibration.

Specifications

 
Dosing Controlon/off, proportional and PID
Dosing TerminalsUp to 5 relays (independently configurable for process variables, Hold & Cleaning functions)
Electromechanical relay SPDT and SPST contact outputs
5A – 250 Vac; 5A – 30 Vdc (resistive load)
Fuse protected: 5A, 250V slow blow fuse
Alarm Relay Set Point

Up to 5 relays (independently configurable for process variables, Hold & Cleaning functions)

Electromechanical relay SPDT and SPST contact outputs
5A – 250 Vac; 5A – 30 Vdc (resistive load)
Fuse protected: 5A, 250V slow blow fuse

Over Dosing Controlyes
System Erroryes
Analog Ouput Signal2 or 4 independent, galvanically isolated outputs
0 – 22 mA configurable as:
0 – 20 mA; 4 – 20 mA
22 mA as alarm signal, configurable option
Analog Ouput Accuracy±2% full scale
Digital Input Signalindependent, galvanically isolated inputs (configurable for Hold & Cleaning functions)
On state: 5 to 24 Vdc, low or high level active
Digital Output SignalRS485
Backlightyes
Power Consumption15VA
Enclosure*Single case ½ DIN, type NEMA4X, IP65 ingress protection
Installation CategoryII
Panel Cutout1/2 DIN (brackets ordered seperately)
Input Channelsone digital input with RS485 interface
pH ElectrodeHI10X6 series – pH and Temperature (ordered seperately)
ORP ElectrodeHI20X4 series – ORP and Temperature (ordered seperately)
Logging TypeInterval log, up to 100 files, maximum 8600 records on each stored file.
When the maximum limit of 100 stored files is reached, the most recent file will automatically erase the oldest one.
Event log, maximum 100 records. When the maximum limit i
ConnectivityRS485 serial port – Remote monitoring and control
USB-C port – Retrieve log files and firmware upgrading
GLPyes
Calibration Timeout Reminderyes
Analog Outputup to 4 based on configuration ordered
DisplayGraphic LCD, 128 x 64 pixel B/W with backlight
Power Supply100 – 240 Vac ±10%; 50/60 Hz; 15VA; fuse protected (2A, 250V slow blow fuse)
Environment-20 to 50 ºC (-4 to 122 ºF); maximum 100% RH non-condensing
IP RatingIP65
DimensionsWidth 144.0 mm (5.7”) x Height 144.0 mm (5.7”) x Depth 151.3 mm (6.0”)
WeightApproximately 1.6 kg (3.5 lb.)
Ordering InformationHI510-0540 universal process controller with 5 relays and 4 analog outputs is supplied with 3m power cable, cable gland set, instrument certificate, and instruction manual.
HI510-0320 universal process controller with 3 relays and 2 analog outputs is supplied with 3m power cable, cable gland set, instrument certificate, and instruction manual.
Notes*For a water tight seal, tighten the front four screws on the front casing to 13.3 lbf·in (1.5 N·m, maximum 2.0 N·m), of torque.

Dodatne informacije

Dodatne informacije

Inputs

3 relays, 2 analog outputs, 5 relays, 4 analog outputs

Povprašajte za ponudbo

Opomba: polja, označena z *, so obvezna.

Ne najdete tistega, kar potrebujete?

V našem katalogu imamo več kot 3.000 izdelkov. Registrirajte se zdaj in prenesite katalog ali pa nas kontaktirajte, skušali Vam bomo pomagati.

Login

Login to your account or create one right now to access to our exclusive content.

Prijava

Prijavite se prek svojega računa ali pa ga sedaj na novo ustvarite prek naših prvovrstnih vsebin.